5 GHz RF Auxiliary input
Exclusive to HD RANGER 2
The HD RANGER 2 optical fibre option comes along with
a 5 GHz RF auxiliary input which can be used among other
applications for direct connection to optical LNBs with 5.4 GHz
output. This RF input covers three bands:
Band I From 2150 MHz to 3000 MHz
Band II From 3400 MHz to 4400 MHz
Band III From 4400 MHz to 5400 MHz
... plus 5 GHz RF input!
THREE IN ONE:
Selective power meter
+ Selective optical converter
+ 5 GHz aux RF input
(optional)
Selective optical power meter
The HD RANGER 2 selective optical power meter combined
with a portable triple laser source such as PROLITE-105 (sold
separetely) forms a complete Optical Loss Test Set to measure
fibre attenuation. This is of great interest in live FTTH/GPON
installations certification or even before they are in service.